Performance Characteristics

Rating: Filters are designed for continuous operation at rated current and voltage. Operating temperature range is -55º C to +125º C. AC filters may be operated at power frequencies up to 400 Hz.

Terminal Style: All filters rated at 10 amps or less have solder type terminals; those rated above 10 amps have stud-type terminals.

Temperature Rise: The case temperature rise shall not exceed 25º C when operated at rated current, voltage, and line frequency.

Dielectric Test: Filters shall withstand the over-voltage dielectric test specified by MIL-PRF-15733 as applicable.

Insulation Resistance: The insulation resistance of these filters shall be in accordance with MIL-PRF-15733.

Voltage Drop: The voltage drop shall not exceed 1 % of rated voltage when the filter is carrying the specified rated current. AC filter voltage drop shall be measured at unity power factor.

Insertion Loss: The loss shown at 0.15 MHz is conservatively rated and is in accordance with MIL-STD-220. Additional data on request.

Terminal Strength: Terminals shall pass the requirements of MIL-PRF-15733.