HEMP Compliance: Per MIL-STD-188-125-1 and MIL-STD-188-125-2 as Power Line (Intrasite) point of entry filter for short (E1) and intermediate (E2) pulses.
Insertion Loss: Standard performance (curve 1) per MIL-STD-220
Leakage Current: < 10% of rated current 10 through 150 amperes, < 1 amp for 5 amp filters
Insulation Resistance: Per MIL-PRF-15733, prior to discharge resistor installation.
Dielectric Withstanding Voltage: 2250 VDC line-to-chassis per MIL-STD-202, Method 301 prior to surge arrestor and discharge resistor installation
Voltage Drop: Less than 1% of rated voltage per paragraph 4.6.8 of ...
HEMP Compliance: Per MIL-STD-188-125-1 and MIL-STD-188-125-2 as Power Line (Intrasite) point of entry filter for short (E1) and intermediate (E2) pulses.
Insertion Loss: high performance (curve 2) per MIL-STD-220
Leakage Current: < 10% of rated current 10 through 150 amperes, <1 amp for 5 amp filters
Insulation Resistance: Per MIL-PRF-15733, prior to discharge resistor installation.
Dielectric Withstanding Voltage: 2250 VDC line-to-chassis per MIL-STD-202, Method 301 prior to surge arrestor and discharge resistor installation
Voltage Drop: Less than 1% of rated voltage per paragraph 4.6.8 of ...