If your system has MIL-STD-461 compliance requirements, many of the DC-DC converters on the market will not be compliant. The EMI filters listed below have been designed to meet this requirement. In addition, custom voltages/current ratings/size can be designed to meet yourmore
Unit of Measure

Specifications

Voltage Rating (DC)

28 V

Current

20 A

Insertion Loss Curve


Typical Insertion Loss Curve - 2

Size


Size - 2

Weight

~150 g

Case Material

Cold Rolled Steel (CRS)

Visual/Mechanical

Per MIL-PRF-15733, Paragraph 4.6.1

Insulation Resistance

10 MΩ minimum line-to-line & line-to-chassis per MIL-STD-202, Method 302

Dielectric Withstanding Voltage

100 VDC line-to-line & line-to-chassis per MIL-STD-202, Method 301

Insertion Loss

Per MIL-STD-220, see graphs

Terminal Strength

Per MIL-PRF-15733

Operating Temperature

-55 to +95 ºC

Storage Temperature

-55 to +105 ºC

Soldering

In accordance with J-STD-001 Class 3