  • Compact, space-saving configurations offering high power performance
  • Superior isolation achieved by utilizing Captor feedthru capacitors
  • Demanding Tempest Requirements? STOP YOUR SEARCH and contact Captor
  • Voltage Rating : 120/230 VAC @ 60 Hz
  • Visual/Mechanical : Per MIL-F-15733, paragraph 4.6.1
  • Capacitance : Per Mil-STD-202, Method 305 @ 1 kHz
  • Insulation Resistance : 1500 M Ω minimum per MIL-STD-202, Method 302 (prior to installation of bleeder resistors)
  • Dielectric Withstanding Voltage : 1000 VDC line-to-line & line-to-chassis per MIL-STD-202, Method 301
  • Insertion Loss : Per MIL-STD 220
  • Voltage Drop : Less than 1% of rated voltage per paragraph 4.6.8 of MIL-F-15733
  • Terminal Strength : Per MIL-STD-202, Method 211
  • Leakage Current : 5 mA maximum, measured per UL standard 1283 at 120 VAC, 60 Hz
  • Voltage Discharge : Unit shall discharge to less than 30 VDC after removal or power
  • Operating Temperature : -55 ºC to +71 ºC

    Can't Find the Correct part for your Specific Application?

    Let us design the exact solution to solve your problem. Our solutions are more cost effective than some of our competitors "catalog" items.
    • Higher Operating Frequency
    • Higher Voltage and Current Ratings
    • Custom chassis designs
    • Custom terminations
    • Application specific testing available upon request
    • Custom Spec Sheets
Unit of Measure

Specifications

Voltage Rating

N/A 120/230 VAC @ 60 Hz

Visual/Mechanical

N/A Per MIL-F-15733, Paragraph 4.6.1

Capacitance

N/A Per MIL-STD-202, Method 305 @ 1 kHz

Insulation Resistance

N/A 1500 MΩ minimum per MIL-STD-202, Method 302 (prior to installation of bleeder resistors)

Dielectric Withstanding Voltage

N/A 1000 VDC line-to-line & line-to-chassis per MIL-STD-202, Method 301

Insertion Loss

N/A Per MIL-STD 220

Voltage Drop

N/A Less than 1% of rated voltage per paragraph 4.6.8 of MIL-F-15733

Terminal Strength

N/A Per MIL-STD-202, method 211

Leakage Current

N/A 5 mA maximum, measured per UL standard 1283 at 120 VAC, 60 Hz

Voltage Discharge

N/A Unit shall discharge to less than 30 VDC after removal or power

Operating Temperature

N/A -55 to +71 ºC

Fig.

N/A
3

Current Rating

N/A 15 A

Dimension A

N/A 6.00 in

Dimension B

N/A 6.00 in

Dimension C

N/A 3.00 in

Input Connection

N/A IEC

Output Connection

N/A 8-32UNC-2A Terms

Insertion Loss Curve

Insertion Loss Curve

N/A
Insertion Loss Curve Figure 6