- Voltage : 0 to 480 Volts
- Current : 0 to 100 Amps
- Frequency : DC to 400 Hz
- Insertion Loss : 100 dB minimum from 14 kHz to 10 GHz
- Operating Temperature : -40 ºC to +71 ºC
- Storage Temperature : -55 ºC to +105 ºC
- Altitude : Maximum of 15,000 feet
- Humidity : 10 to 90 Percent
- Fungus : Non-nutritive materials are used
- Corrosion : Hermetically sealed steel or aluminum enclosures with tin-lead plating
HEMP/EMP Filter # |
Voltage (Vrms) |
Voltage (Peak) |
Current |
Frequency |
DCR |
DWV (DC) |
CAD |
---|---|---|---|---|---|---|---|
A-9597 | Voltage (Vrms) N/A 35 | Voltage (Peak) N/A 50 | Current N/A 2 A | Frequency N/A DC-60 Hertz | DCR N/A ≤ 0.3 Ω | DWV (DC) N/A 200 V | CAD N/A |
A-9598 | Voltage (Vrms) N/A 132 | Voltage (Peak) N/A 187 | Current N/A 2 A | Frequency N/A DC-60 Hertz | DCR N/A ≤ 1.0 Ω | DWV (DC) N/A 600 V | CAD N/A |
A-9599 | Voltage (Vrms) N/A 132 | Voltage (Peak) N/A 187 | Current N/A 1/2 A | Frequency N/A DC-60 Hertz | DCR N/A ≤ 6.1 Ω | DWV (DC) N/A 600 V | CAD N/A |
A-9600 | Voltage (Vrms) N/A 35 | Voltage (Peak) N/A 50 | Current N/A 1/2 A | Frequency N/A DC-60 Hertz | DCR N/A ≤ 1.5 Ω | DWV (DC) N/A 200 V | CAD N/A |
A-8292 | Voltage (Vrms) N/A 125 | Voltage (Peak) N/A 177 | Current N/A 5 A | Frequency N/A DC to 60 Hertz | DCR N/A ≤ 0.5 Ω | DWV (DC) N/A 600 V | CAD N/A |
A-8945 | Voltage (Vrms) N/A 120 | Voltage (Peak) N/A | Current N/A 20 A | Frequency N/A 60 Hertz | DCR N/A ≤ 0.10 Ω | DWV (DC) N/A 800 V | CAD N/A |