- Voltage Rating: 277/480 VAC @ 60 Hz
- Current Rating: 5 through 150 amperes
- HEMP Compliance: Per MIL-STD-188-125-1 and MIL-STD-188-125-2 as Power Line (Intrasite) point of entry filter for short (E1) and intermediate (E2) pulses.
- Insertion Loss: Standard performance (curve 1) per MIL-STD-220
- Leakage Current: < 10% of rated current 10 through 150 amperes, < 1 amp for 5 amp filters
- Insulation Resistance: Per MIL-PRF-15733, prior to discharge resistor installation.
- Dielectric Withstanding Voltage: 2250 VDC line-to-chassis per MIL-STD-202, Method 301 prior to surge arrestor and discharge resistor installation
- Voltage Drop: Less than 1% of rated voltage per paragraph 4.6.8 of MIL-PRF-15733
- Voltage Discharge: Discharge to less than 30 Volts within 30 s after removal of power
- Operating Temperature: -40 ºC to +65 ºC
- Storage Temperature: -55 ºC to +105 ºC
Item # |
Item Name |
Number of Circuits |
Dimension A |
Dimension B |
Dimension C |
CAD |
---|---|---|---|---|---|---|
A-10540 | N/A 5 Ampere (A) Current Power Line Stand Alone HEMP Filter Standard Performance | Number of Circuits N/A 2 | Dimension A N/A 9.00 in | Dimension B N/A 30.0 in | Dimension C N/A 5.5 in | CAD N/A |
A-10541 | N/A 5 Ampere (A) Current Power Line Stand Alone HEMP Filter Standard Performance | Number of Circuits N/A 3 | Dimension A N/A 13.5 in | Dimension B N/A 30.0 in | Dimension C N/A 5.5 in | CAD N/A |
A-10542 | N/A 5 Ampere (A) Current Power Line Stand Alone HEMP Filter Standard Performance | Number of Circuits N/A 4 | Dimension A N/A 18.00 in | Dimension B N/A 30.0 in | Dimension C N/A 5.5 in | CAD N/A |
A-10543 | N/A 10 Ampere (A) Current Power Line Stand Alone HEMP Filter Standard Performance | Number of Circuits N/A 2 | Dimension A N/A 9.00 in | Dimension B N/A 30.0 in | Dimension C N/A 5.5 in | CAD N/A |
A-10544 | N/A 10 Ampere (A) Current Power Line Stand Alone HEMP Filter Standard Performance | Number of Circuits N/A 3 | Dimension A N/A 13.5 in | Dimension B N/A 30.0 in | Dimension C N/A 5.5 in | CAD N/A |
A-10545 | N/A 10 Ampere (A) Current Power Line Stand Alone HEMP Filter Standard Performance | Number of Circuits N/A 4 | Dimension A N/A 18.00 in | Dimension B N/A 30.0 in | Dimension C N/A 5.5 in | CAD N/A |
A-10546 | N/A 20 Ampere (A) Current Power Line Stand Alone HEMP Filter Standard Performance | Number of Circuits N/A 2 | Dimension A N/A 12.0 in | Dimension B N/A 31.0 in | Dimension C N/A 5.5 in | CAD N/A |
A-10547 | N/A 20 Ampere (A) Current Power Line Stand Alone HEMP Filter Standard Performance | Number of Circuits N/A 3 | Dimension A N/A 18.00 in | Dimension B N/A 31.0 in | Dimension C N/A 5.5 in | CAD N/A |
A-10548 | N/A 20 Ampere (A) Current Power Line Stand Alone HEMP Filter Standard Performance | Number of Circuits N/A 4 | Dimension A N/A 24.0 in | Dimension B N/A 31.0 in | Dimension C N/A 5.5 in | CAD N/A |
A-10549 | N/A 30 Ampere (A) Current Power Line Stand Alone HEMP Filter Standard Performance | Number of Circuits N/A 2 | Dimension A N/A 12.0 in | Dimension B N/A 31.0 in | Dimension C N/A 5.5 in | CAD N/A |
A-10550 | N/A 30 Ampere (A) Current Power Line Stand Alone HEMP Filter Standard Performance | Number of Circuits N/A 3 | Dimension A N/A 18.00 in | Dimension B N/A 31.0 in | Dimension C N/A 5.5 in | CAD N/A |
A-10551 | N/A 30 Ampere (A) Current Power Line Stand Alone HEMP Filter Standard Performance | Number of Circuits N/A 4 | Dimension A N/A 24.0 in | Dimension B N/A 31.0 in | Dimension C N/A 5.5 in | CAD N/A |
A-10552 | N/A Cabinet with 60 Ampere (A) Current Filter Standard Performance | Number of Circuits N/A 2 | Dimension A N/A 14.0 in | Dimension B N/A 40.0 in | Dimension C N/A 9.0 in | CAD N/A |
A-10553 | N/A Cabinet with 60 Ampere (A) Current Filter Standard Performance | Number of Circuits N/A 3 | Dimension A N/A 22.0 in | Dimension B N/A 40.0 in | Dimension C N/A 9.0 in | CAD N/A |
A-10554 | N/A Cabinet with 60 Ampere (A) Current Filter Standard Performance | Number of Circuits N/A 4 | Dimension A N/A 28.0 in | Dimension B N/A 40.0 in | Dimension C N/A 9.0 in | CAD N/A |
A-10555 | N/A Cabinet with 100 Ampere (A) Current Filter Standard Performance | Number of Circuits N/A 2 | Dimension A N/A 14.0 in | Dimension B N/A 40.0 in | Dimension C N/A 9.0 in | CAD N/A |
A-10556 | N/A Cabinet with 100 Ampere (A) Current Filter Standard Performance | Number of Circuits N/A 3 | Dimension A N/A 22.0 in | Dimension B N/A 40.0 in | Dimension C N/A 9.0 in | CAD N/A |
A-10557 | N/A Cabinet with 100 Ampere (A) Current Filter Standard Performance | Number of Circuits N/A 4 | Dimension A N/A 28.0 in | Dimension B N/A 40.0 in | Dimension C N/A 9.0 in | CAD N/A |
A-10558 | N/A Cabinet with 150 Ampere (A) Current Filter Standard Performance | Number of Circuits N/A 2 | Dimension A N/A 14.0 in | Dimension B N/A 44.0 in | Dimension C N/A 12.0 in | CAD N/A |
A-10559 | N/A Cabinet with 150 Ampere (A) Current Filter Standard Performance | Number of Circuits N/A 3 | Dimension A N/A 22.0 in | Dimension B N/A 44.0 in | Dimension C N/A 12.0 in | CAD N/A |
A-10560 | N/A Cabinet with 150 Ampere (A) Current Filter Standard Performance | Number of Circuits N/A 4 | Dimension A N/A 28.0 in | Dimension B N/A 44.0 in | Dimension C N/A 12.0 in | CAD N/A |