CAD (0)
  • Cart is empty

Specifications

  • Voltage Rating: 277/480 VAC @ 60 Hz
  • Current Rating: 50 through 800 Amperes
  • Insulation Resistance: Per MIL-PRF-15733, prior to discharge resistor installation.
  • Dielectric Withstanding Voltage: 2250 VDC line-to-chassis per MIL-STD-202, Method 301 prior to installation of discharge resistor
  • Voltage Drop: Less than 1% of rated voltage per paragraph 4.6.8 of MIL-PRF-15733
  • Voltage Discharge: Discharge to less than 30 Volts within 30s after removal of power
  • Operating Temperature: -40° C to +65° C
  • Storage Temperature: -55° C to +105° C
  • Insertion Loss: Measured per MIL-STD-220
Enclosure
  • Modified: NEMA 1 type enclosure
  • Cabinet Material: Stainless Steel construction
  • Filter insert case material: Cold rolled steel construction with a corrosion resistant plating
  • Epoxy paint optional
  • Shielding effectiveness measured on clean side greater than 100 dB from 14KHz or 100KHz to 10 GHz
  • Dual removable access covers
1 - 25 of 42 | Results Per Page | View | Unit of Measure
1 2 

Item #

Item Name

Alternating Current (AC) Voltage at 60 Hertz (Hz)

Operating Temperature

Number of Lines

Current Rating

N/A 2 Line 50 Ampere (A) Current Rating High Performance Shielded Facility Room Power Line Filter N/A 270 V480 V N/A -40 to +65 ºC N/A 2 N/A 50 A
N/A 3 Line 50 Ampere (A) Current Rating High Performance Shielded Facility Room Power Line Filter N/A 270 V480 V N/A -40 to +65 ºC N/A 3 N/A 50 A
N/A 4 Line 50 Ampere (A) Current Rating High Performance Shielded Facility Room Power Line Filter N/A 270 V480 V N/A -40 to +65 ºC N/A 4 N/A 50 A
N/A 2 Line 100 Ampere (A) Current Rating High Performance Shielded Facility Room Power Line Filter N/A 270 V480 V N/A -40 to +65 ºC N/A 2 N/A 100 A
N/A 3 Line 100 Ampere (A) Current Rating High Performance Shielded Facility Room Power Line Filter N/A 270 V480 V N/A -40 to +65 ºC N/A 3 N/A 100 A
N/A 4 Line 100 Ampere (A) Current Rating High Performance Shielded Facility Room Power Line Filter N/A 270 V480 V N/A -40 to +65 ºC N/A 4 N/A 100 A
N/A 2 Line 150 Ampere (A) Current Rating High Performance Shielded Facility Room Power Line Filter N/A 270 V480 V N/A -40 to +65 ºC N/A 2 N/A 150 A
N/A 3 Line 150 Ampere (A) Current Rating High Performance Shielded Facility Room Power Line Filter N/A 270 V480 V N/A -40 to +65 ºC N/A 3 N/A 150 A
N/A 4 Line 150 Ampere (A) Current Rating High Performance Shielded Facility Room Power Line Filter N/A 270 V480 V N/A -40 to +65 ºC N/A 4 N/A 150 A
N/A 2 Line 200 Ampere (A) Current Rating High Performance Shielded Facility Room Power Line Filter N/A 270 V480 V N/A -40 to +65 ºC N/A 2 N/A 200 A
N/A 3 Line 200 Ampere (A) Current Rating High Performance Shielded Facility Room Power Line Filter N/A 270 V480 V N/A -40 to +65 ºC N/A 3 N/A 200 A
N/A 4 Line 200 Ampere (A) Current Rating High Performance Shielded Facility Room Power Line Filter N/A 270 V480 V N/A -40 to +65 ºC N/A 4 N/A 200 A
N/A 2 Line 300 Ampere (A) Current Rating High Performance Shielded Facility Room Power Line Filter N/A 270 V480 V N/A -40 to +65 ºC N/A 2 N/A 300 A
N/A 3 Line 300 Ampere (A) Current Rating High Performance Shielded Facility Room Power Line Filter N/A 270 V480 V N/A -40 to +65 ºC N/A 3 N/A 300 A
N/A 4 Line 300 Ampere (A) Current Rating High Performance Shielded Facility Room Power Line Filter N/A 270 V480 V N/A -40 to +65 ºC N/A 4 N/A 300 A
N/A 2 Line 400 Ampere (A) Current Rating High Performance Shielded Facility Room Power Line Filter N/A 270 V480 V N/A -40 to +65 ºC N/A 2 N/A 400 A
N/A 3 Line 400 Ampere (A) Current Rating High Performance Shielded Facility Room Power Line Filter N/A 270 V480 V N/A -40 to +65 ºC N/A 3 N/A 400 A
N/A 4 Line 400 Ampere (A) Current Rating High Performance Shielded Facility Room Power Line Filter N/A 270 V480 V N/A -40 to +65 ºC N/A 4 N/A 400 A
N/A 2 Line 800 Ampere (A) Current Rating High Performance Shielded Facility Room Power Line Filter N/A 270 V480 V N/A -40 to +65 ºC N/A 2 N/A 800 A
N/A 3 Line 800 Ampere (A) Current Rating High Performance Shielded Facility Room Power Line Filter N/A 270 V480 V N/A -40 to +65 ºC N/A 3 N/A 800 A
N/A 4 Line 800 Ampere (A) Current Rating High Performance Shielded Facility Room Power Line Filter N/A 270 V480 V N/A -40 to +65 ºC N/A 4 N/A 800 A
N/A 2 Line 50 Ampere (A) Current Rating Standard Performance Shielded Facility Room Power Line Filter N/A 270 V480 V N/A -40 to +65 ºC N/A 2 N/A 50 A
N/A 3 Line 50 Ampere (A) Current Rating Standard Performance Shielded Facility Room Power Line Filter N/A 270 V480 V N/A -40 to +65 ºC N/A 3 N/A 50 A
N/A 4 Line 50 Ampere (A) Current Rating Standard Performance Shielded Facility Room Power Line Filter N/A 270 V480 V N/A -40 to +65 ºC N/A 4 N/A 50 A
N/A 2 Line 100 Ampere (A) Current Rating Standard Performance Shielded Facility Room Power Line Filter N/A 270 V480 V N/A -40 to +65 ºC N/A 2 N/A 100 A
1 - 25 of 42 | Results Per Page | View | Unit of Measure
1 2